Polypipe 8 Zone Wiring Centre 230v UFH8ZW

(Code: UFH8ZW)
Polypipe
The is an 8 Zone wiring centre for use with Polypipe 230v thermostats.

The UFH8ZW can be used to control any actuator or valve which requires a 230v AC signal to open. For mid position valves and those requiring a closing signal, a changeover relay is required. At the same time the UFH8ZW offers the ability to operate a boiler or other heat source through a volt free output.

Additional outputs designed for use with underfloor heating systems are also included as standard. These are the pump and valve outputs which would normally operate a manifold pump or a manifold valve.

Zone 8 can be used as an isolated radiator zone by using the UFH/RAD switch. If the switch is set to RAD; When zone 8 calls for heat this will provide an output to a radiator zone valve and the boiler, but WILL NOT heating pump/valve output If the switch is set to UFH; When Zone 8 calls for heat, this will act as an underfloor heating zone, by enabling the actuator, boiler and pump/valve outputs. Any output which is not needed can be ignored
£ 84.10
1500g
@import url(https://fonts.googleapis.com/css?family=Lato:100,400); #the-final-countdown { background: #333; font-family: 'Lato', sans-serif; text-align: center; color: #eee; text-shadow: 1px 1px 5px black; padding: 1rem 0; font-size: 3rem; border: 1px solid #000; }
PAYPAL CREDIT
Finance options available
EXPRESS DELIVERY*
Order before 1pm
FREE DELIVERY
On orders over £50*
RATED EXCELLENT
Read reviews
  1. Description of the article Polypipe UFH8ZW- 8 Zone Wiring Centre - 230v Underfloor heating control



    UFH8ZW can be used to control any actuator or valve which requires a 230v AC signal to open. For mid position valves and those requiring a closing signal, a changeover relay is required. At the same time the UFH8ZW offers the ability to operate a boiler or other heat source through a volt free output.

    Additional outputs designed for use with underfloor heating systems are also included as standard. These are the pump and valve outputs which would normally operate a manifold pump or a manifold valve.

    Zone 8 can be used as an isolated radiator zone by using the UFH/RAD switch. If the switch is set to RAD; When zone 8 calls for heat this will provide an output to a radiator zone valve and the boiler, but WILL NOT heating pump/valve output If the switch is set to UFH; When Zone 8 calls for heat, this will act as an underfloor heating zone, by enabling the actuator, boiler and pump/valve outputs. Any output which is not needed can be ignored.
  2. ✔ 8 Heating Zones
    ✔ The UFH8ZW can be mounted directly to a wall using four screws or alternatively, the unit can be DIN rail mounted
    ✔ Compatible wit Heatmiser controls
    ✔ Genuine Polypipe Product
    ✔ Part number: UFH8ZW